High Voltage Spark Gap-Switches
| Spark-Gap Switch Model No. | Operating Voltage Range KV | Max Peak Current KA | Max Charge Transfer | Inductance NH | Action MJ/Ω | Design Shot Life (x 1000) at Full Rating | Dimentions DIA. X HT (LxWxH) | |
| Inches | Millimeters | |||||||
|
40264 |
25-100 |
100 |
0.3 |
<40 |
N/A |
10 |
5.8 x 2.7 |
148 x 69 |
|
40265 |
25-100 |
100 |
0.15 |
<40 |
N/A |
10 |
5.8 x 2.7 |
148 x 69 |
|
40302 |
10-120 |
1200 |
10 |
<20 |
N/A |
5 |
19.6 X 7.7 X 7.8 |
498 x 196 x 198 |
|
40364 |
25-100 |
120 |
0.5 |
<40 |
N/A |
10 |
5.8 x 2.7 |
148 x 69 |
|
40369 |
25-60 |
350 |
5 |
<100 |
N/A |
10 |
10.5 x 9.9 |
267 x 252 |
|
40864 |
50-100 |
120 |
0.5 |
<40 |
N/A |
10 |
5.8 x 2.7 |
148 x 69 |
|
40964 |
15-50 |
35 |
0.3 |
<20 |
N/A |
10 |
5.0 x 1.5 |
127 x 38 |
|
50264 |
50-200 |
100 |
0.1 |
<75 |
N/A |
10 |
5.0 x 1.5 |
127 x 38 |
|
ST-300E |
0-5 5 |
600 |
540 |
<200 |
135 |
160 kC |
9 x 11.5 |
229 x 292 |
|
T-150 |
20-40 |
300 |
120 |
<70 |
16 |
40 kC |
8 x 11 |
203 x 279 |
|
T-508 |
30-120 |
150 |
2 |
≈150 |
N/A |
2 |
8 x 9 |
203 x 229 |
|
T-508A |
60-200 |
150 |
2 |
≈150 |
N/A |
2 |
8x9 |
203 x 229 |
|
T-508AX |
60-200 |
150 |
2 |
≈150 |
N/A |
2 |
8 x 9 |
203 x 229 |
| Spark-Gap Switch Model No. | External Operating Environment | External Dielectric Gas | Internal Pressure Range PSIG Sea Level | Type Trigger Electrode | Trigger Electrode Biasing | Fig. No. | Jitter | ||
| Model 40168 | Model 40268 | Model 40151 | |||||||
| 40264 | SF6, oil | Syn. air | 15-85 | IRR | V/2 | 1 | <2 | <1 | N/A |
| 40265 | SF6, oil | Syn. air | 15-85 | FD | V/2 | 1 | <5 | <2 | N/A |
| 40302 | Air, SF6, oil | SF6 Argon/ Oxygen Argon | 12-60 | FD | V/2 or V/3 | 3 | <5 | <5 | <2 |
| 40364 | SF6, oil | Syn. air | 15-85 | IRR | V/2 | 1 | <5 | <1 | N/A |
| 40369 | SF6, oil | Syn. air | 15-50 | IRR/SC | V/3 | 2 | <7 | <5 | <5 |
| 40864 | SF6, oil | Syn. air | 15-55 | IRR | V/2 | 1 | <5 | <1 | N/A |
| 40964 | Air, SF6, oil | Syn. air | 5-50 | IRR/SC | V/3 | 5 | <1 | N/A | N/A |
| 50264 | Air, SF6, oil | Syn. air | 10-30 | IRR/SC | V/3 | 5 | - | - | - |
| ST-300E | Air | Dry Air | 0-50 | SI | N/A | 4 | N/A | N/A | N/A |
| T-150 | Air | Dry Air | 0-55 | TIG | N/A | 8 | N/A | N/A | N/A |
| T-508 | SF6, oil | Syn. air or SF6 | 30 | FD | V/2 | 6 | - | - | - |
| T-508A | SF6, oil | Syn. air or SF6 | 30 | FD | V/2 | 7 | - | - | - |
| T-508AX | SF6, oil | Syn. air or SF6 | 30 | FD | V/2 | 7 | - | - | - |
AVAILABLE FILES
Library of Datasheets
If you'd like to dive deeper into the full specifications or explore each component in detail, simply click below to view the complete set of datasheets
Spark Gap Switches Brochure
Coming Soon
Specifications for the Model 40369 Spark-Gap Switch
Coming Soon
ST-300 High-Action Spark Gap Switch
Coming Soon
T-508 Datasheet
Coming Soon
PULSED POWER COMPONENTS
Model 40302 Rail-Gap Switch Specifications
|
Item |
Parameter |
Specification |
|
Dimension
|
Length |
19.6 in. (50 cm) |
|
Active Switching Length |
12 in. (30 cm) |
|
|
Width |
7.73 in. (20 cm) |
|
|
Height |
7.84 in. (20 cm) |
|
|
External Operating Environment
|
Dielectric |
Air, SF6 or oil |
|
Temperature |
60 to 100°F (15 to 38°C) |
|
|
Altitude |
0 to 8000 ft. (0 to 2500 m) |
|
|
Relative Humidity |
5 to 95 percent |
|
|
Output
|
Voltage range |
10 to 120 kV(a) |
|
Maximum peak current |
1.2 MA |
|
|
Maximum charge transfer |
10C |
|
|
Inductance |
20 nH |
|
|
Jitter (1σ) |
< 2.0 ns |
|
|
Trigger
|
Amplitude (maximum)(b) |
100 kV |
|
Rate of rise (minimum)(c) |
5 kV/ns |
|
|
Dielectric Gas (25 to 120 kV Operation)
|
Grade |
Instrument or better |
|
Percent SF6 |
15% +0.5, -0.0 by volume |
|
|
Percent argon |
85% +0.0, -0.5 by volume |
|
|
Impurities
|
< 5 ppm hydrocarbons by weight |
|
|
<1000 ppm other impurities by weight |
||
|
<5 ppm H2O by weight |
||
|
<1 ppm hydrogen fluoride by weight |
||
|
Filtration |
No particulates > 5 microns |
|
|
Dielectric Gas (10 to 30 kV Operation)(d)
|
Grade |
Instrument or better |
|
Percent oxygen |
10% +1.0, -0.0 by volume |
|
|
Percent argon |
90% +0.0, -1.0 by volume |
|
|
Impurities
|
<5 ppm hydrocarbons by weight | |
|
<1000 ppm other impurities by weight |
||
|
<5 ppm H2O by weight |
||
|
<1 ppm hydrogen fluoride by weight |
||
|
Filtration |
No particulates > 5 microns |
|
Available Files
Library of Datasheets
If you'd like to dive deeper into the full specifications or explore each component in detail, simply click below to view the complete set of datasheets.
Model 40302 Rail-Gap Switch
Coming Soon

Contact us
Let’s Start the Conversation
Whether you’re looking for detailed product information, a custom engineering solution, or partnership opportunities - our experts are here to help. Reach out to discuss your project or request tailored technical support.